Copper Wire Braid Shielded Control Cable
Tags : Control cables,PVC Insulated and sheathed cable,braid shielded control cable
Summary: PVC insulated and sheathed with copper wire braid shielded control cable is worked as control, monitor or protect cable under AC rated voltage 450/750V or less than it.
Description
Standards
The control cable can be produced according to the standard GB9330-1988, IEC, DIN, BS and the factory can also manufacture the cables in accordance with other standards.
Braid shielded control cable Detail:
1.1 Rated voltage U0/U is 450/750V
U0~Valid value of the voltage between main insulated conductor and earthing (metal shield, metal sheath of environment dielectric).
U~valid value of voltage between any two phases conductor in multicourse cable or single core cable system.
When AC. System is applied, the rated voltage of cables should be at least equal to the nominal voltage of the system. When DC. System is applied; the nominal voltage of this system should not be more than the rated voltage of the system by 1.5 times.
1.2 The permitting long-term operating temperature of cable conductor should be
PVC insulation: 70℃
XLPE: 90℃
Technical data:
Rated voltage: 450/750V
Max. Operating Temp of Conductor: under normal 70℃, emergency ( 105℃), short circuit no more than 5s (160℃)
Min. Ambient Temperature during installation: 0℃, after installation and only when cable is in a fixed position
Braid shielded control cable Advantages
it has the advantages of not only high mechanical strength, good ambient stress resistance, excellent electrical properties and anti-chemical corrosion, but also simple construction, light weight and easy to use.This type of cable is applicable for connection of elecctrical equipment, controlling, minitoring and protective system with A.C. rated voltage up to and including 450/750V.
Copper wire braid shielded control cable Scope of Application:The control cable are suitable for the wiring of electrical controlling equipment and instrument, monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.
Service Conditions
(1) The long-time working temperature of conductor of PVC insulated cable is 70℃
The long-time working temperature of conductor of XLPE insulated cable is 90℃
(2) The temperature for laying the cables cannot be lower than 0℃.
Permissible bending radius(r):
armoured or copper-tape screened cable:r≥12D;
shielded flexible cable:r≥6D;
D: outer diameter of the cable;
Specifications
Type |
Name |
Section Area(mm2) |
No. of Core |
Application Site |
KVV |
Copper Conductor, PVC Insulated and Sheathed Control Cable |
0.75, 1.0, 1.5, 2.5 |
2-16 |
Permanent installation indoors, in cable ditches or pipes. |
|
|
4, 6 |
2-14 |
|
|
|
10 |
2-10 |
|
KVVP |
Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Control Cable |
0.75, 1.0, 1.5, 2.5 |
2-61 |
Permanent installation indoors, in cable ditches or pipes where shielding is required. |
|
|
4, 6 |
2-14 |
|
|
|
10 |
2-10 |
|
KVVP |
Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable |
0.75, 1.0, 1.5, 2.5 |
4-10 |
Permanent installation indoors, in cable ditches or pipes where shielding is required. |
|
|
4, 6 |
7-61 |
|
|
|
10 |
4-10 |
|
KVV22 |
Copper Conductor, PVC Insulated and Sheathed, Steel-tape Armored Control Cable |
0.75, 1.0, 1.5, 2.5 |
7-61 |
Permanent installation indoors, in cable ditches, pipes or under ground. Be able to bear stronger outer mechanical force. |
|
|
4,6 |
4-14 |
|
|
|
10 |
4-14 |
|
KVVR |
Copper Conductor, PVC Insulated and Sheathed Flexible Control Cable |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
KVVRP |
Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Flexible Control Cable |
0.5,0.75,1.0 |
4-61 |
Installation indoors where flexibility shielding and movability are required. |
|
|
1.5,2.5 |
4-48 |
|
KYJV |
Copper Conductor, XLPE insulated and PVC Sheathed Control Cable |
0.75,1.0,1.5, 2.5 |
2-16 |
Permanent installation indoors, in cable ditches or pipes. |
|
|
4,6 |
2-14 |
|
|
|
10 |
2-10 |
|
KYJVP |
Copper Conductor, XLPE Insulated, Braiding Shielded, PVC Sheathed Control Cable |
0.75,1.0,1.5, 2.5 |
2-61 |
Permanent installation indoors, in cable ditches or pipes where shielding is required. |
|
|
4,6 |
2-14 |
|
|
|
10 |
2-10 |
|
KYJV22 |
Copper Conductor, XLPE Insulated, Steel-tape Armored, PVC Sheathed Control Cable |
0.75,1.0,1.5, 2.5 |
7-61 |
Permanent installation indoors, in cable ditches, pipes or underground. Be able to bear stronger outer mechanical force. |
|
|
4,6 |
4-14 |
|
|
|
10 |
4-10 |
|
KYJVP2 |
Copper Conductor, XLPE Insulated, Copper tape Screened, PVC Sheathed Control Cable |
0.75, 1.0, 1.5, 2.5 |
7-61 |
Permanent installation indoors, in cable ditches or pipes where shielding is required. |
|
|
4, 6 |
4-14 |
|
|
|
10 |
4-10 |
|
KYJVR |
Copper Conductor, XLPE insulated, PVC Sheathed Flexible Control Cable |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required. |
KYJVRP |
Copper Conductor, XLPE insulated, Braiding Shielded, PVC Sheathed Flexible Control Cable |
0.5,0.75,1.0 |
4-61 |
Installation indoors where flexibility shielding and movability are required. |
Related Products
Single Core PVC cable--BV
Tags :
InquiryNYBY Cable
Tags :NYBY Cables,PVC insulated cables,LV STA armored cable
InquiryFlexible Mineral Insulated Isolation Type Fire Resistant Cab...
Tags :Fire Resistant Cable,Mineral Insulated Cable,FRC
InquiryCopper Metallic Sheathed Fire Resistant Cable (YTTW)
Tags :Fire Resistant Cable,YTTW,Copper Metallic Sheathed Fire Resistant Cable
InquiryFlexible Mineral Insulated Fire Resistant Cable (BBTRZ)
Tags :Mineral insulated cables,Fire Resistant Copper cable,BBTRZ
InquirySingle Core Flexible Cable--RV
Tags :RV Cable,Electrical Wire and Cables,PVC Insulated Flexible Wire
Inquiry
GET IN TOUCH
If you have any questions, please fill in the following information and we will respond to you in time.